ICx Technologies Home
Detectors
NaI(Tl): 1.4'' diameter x 2'' long (35 x 51 mm) with PMT, magnetic shield and shock mounting
GM Tube: for high dose rate measurements
Optional 3He Detector for neutron detection
Energy Response
NaI(Tl): 25 keV to 3 MeV
GM Tube: 60 keV to 1.6 MeV
Dose Measurement Specifications
Sensitivity (137Cs): >500 cps/μSv/h (5000 cps/mrem/h)
Dose Rate Range: 10 nSv/h - 1 Sv/h (1μrem/h - 100 rem/h)
Alarm Levels
Finder Mode: One present level
Dose Rate Mode: Four present levels
Alarm: red LED for gamma
Optional: blue LED for neutron
Display
Type: Monochrome LCD 2.4'' x 1.7'' (61 x 43 mm) Backlit
Controls
Batteries: Low Battery alarm via flashing display and audible beep
Language: German, English, French, Spanish, Russian
Environmental
Operating: -15 to +55 °C; +5 to +131 °F
Storage: -30 to +70 °C; -22 to +158 °F
Power Requirements
Batteries: 4 each size AA, LR6, 1.2-1.8 V NiMH (2500 mAh), rechargeable
Operating time: > 8 hours in dose rate mode
Housing
  Aluminum, powder painted
Dimensions
Housing: 11'' x 3.5'' x 2.8'' (280 x 90 x 70 mm)
Weight: 2.6 pounds (1180 g) including batteries
Model Information
ironMAN-NG: Standard unit
1.4” diameter x 2.0” long (35 x 51 mm) NaI(Tl), GM tube,
holster and battery charger
ironMAN-NGH: Standard unit with 3He neutron detector
ironMAN-X-NG: Standard unit with telescopic extension
ironMAN-X-NGH: Standard unit with 3He neutron detector and telescopic extension
Optional: Carrying case